資料介紹:
2.1 Key to numbered items on Terminal Layout diagram
1. 24V DC transmission power for the network is supplied by the stabilized power supply.
2. The shielded twisted pair cables connect the FX0N-16NT to the network. The SDA/SDB terminals
of the previous station should be connected to the RDA/RDB terminals of this station. The SDA/SDB
terminals of this station should be connected to the RDA/RDB terminals of the next station.
Keep these transmission cables away from all power cables. Do not allow power cables and
transmission cables to share the same duct.
3. Use one-point grounding (Class 3 ground, 100 Ω or less) for the shielding of the twisted pair
cable on the sending or receiving sides.
4. See section 3.6 for use of the ECM (Emergency Clear Mode) terminal.
2.2 Use of crimp-style terminals
Use crimp-style terminals of the indicated dimensions.
6.2 mm (0.24
inch) or less
擴展模塊 FX2N-4DA
晶體管輸出模塊 FX2N-8EYT
PLC FX1N-24MR-D
PLC FX1S-30MR-ES/UL
可編程控制器 FX1N-40MT-001
輸入輸出模塊 FX2N-8ER-ES/UL
定位模塊 FX2N-10GM
晶體管輸出單元 FX0N-40ET
plc FX1S-14MT-001
PLC FX2NC-64MT-D/UL
PLC FX3U-128MR/ES-A
終端模塊用的輸入輸出電纜 FX-16E-300CAB-R
PLC FX2NC-16MR-T-DS
終端模塊 FX-16EYT-TB
擴展板 FX3G-8AV-BD
PLC FX2N-80MR-D
擴展模塊 FX2N-2DA
模擬量輸入模塊 FX2N-4AD
速輸出用適配器 FX3U-2HSY-ADP
模擬量輸入用適配器 FX3U-4AD-ADP
模擬量輸入模塊 FX2N-8AD
PLC FX2N-16MT-001
PLC FX1S-10MT-001
PLC FX1S-30MT-ES/UL
PLC FX2N-32MR-001
輸入擴展板 FX2N-4EX-BD
AS-I主站模塊 FX2N-32ASI-M
PLC FX1N-14MT-ES/UL
PT100型溫度傳感器用適配器 FX3U-4AD-PT-ADP
顯示模塊 FX1N-5DM